Stop apcupsd. Jun 16, 2006 · Why apcupsd? Because it works.

Stop apcupsd conf. conf in an editor during install (see following sections) Windows instaler will interactively ask if you want the service to run - let it pick the defaults Jan 4, 2002 · DESCRIPTION Apcupsd can be used for controlling APC UPSes. SUB = The low-level unit activation state, values depend on unit type. JOB = Pending job for the unit. org, a friendly and active Linux Community. Apr 1, 2020 · hi guys, i have a smart APC Smart-UPS X 1500VA hooked up to my system and is is not reporting load properly as per below: As far as I know it is hooked up by the origianal USB cable. This blog post explains how to install and configure apcupsd. conf file based on reading the manual, but it just won't connect. Start apcupsd service first. I am not an apcupsd expert, but there is likely nothing you should have to do to achieve this. ". conf v1. apctest If you are able to see the following menu, than continue setting, if not review two configured file we had set and check is there any error. systemctl stop apcupsd Do UPS test by entering “apctest”. apcupsd communicates with the UPS usi Start and stop links are installed automatically to start and stop the daemon when rebooting but these may fail to work successfully until you have adjusted the configuration file to match your setup. During a power failure, apcupsd informs users about the loss of utility power and that a shutdown may occur. If power is not restored the server must shutdown when the battery is exhausted. Jun 9, 2019 · Stop apcupsd service before check you UPS. Alternatively, there are simple stopapcupsd and startapcupsd scripts in the examples directory, or you can modify one of the scripts in the distributions directory to meet your needs. when i run the apctest command i get this Mar 14, 2012 · I see your sudo service apcupsd status reports otherwise, but for me on Ubuntu 16. I know how to start the server: sudo /etc/apcupsd/apcupsd start (See the man Hi msinklair, thanks for the info, was trying to stop apcupsd to run apctest but I appear not to be able to stop apcusd which I guess is me typing in the wrong thing in the wrong place. Sep 11, 2018 · This should be simple, but I am stuck figuring it out. systemctl stop apcupsd apctest 1) Test kill UPS power 2) Perform self-test 3) Read last self-test result 4) View/Change battery date 5) View manufacturing date 6) View/Change alarm behavior 7) View/Change sensitivity 8) View/Change low transfer voltage 9) View/Change high transfer voltage Mar 8, 2024 · Unfortunately, the apctest command conflicts with the apcupsd daemon, so you need to stop apcupsd temporarily. 14. Remove the # (pound sign) on the line #SELFTEST 336, save the file, restart the apcupsd service / daemon. By joining our community you will have the ability to post topics, receive our newsletter, use the advanced search, subscribe to threads and access many other special features. I've installed this program on another computer without a problem. generalization of SUB. Sep 2, 2015 · Windows install will automatically start apcupsd. If I click save again, the above observed behavior repeats. During a power failure, apcupsd will inform the users about the power failure and that a DESCRIPTION The apcupsd daemon controls the operation of most American Power Conversion Corp (APC) UPSes. Running on See full list on cyberciti. Pass --all to see loaded but inactive Sep 2, 2016 · My PI3 cluster is connected to an APC SmartUPS using a usb cable and I would like to detect a power failure. Aug 31, 2020 · You are now ready to start the apcupsd service. Join our community today! Note that registered members Sep 20, 2008 · UNIT LOAD ACTIVE SUB JOB DESCRIPTION apcupsd. What I wanted to achieve is after shutting down pfSense, I want to power off the UPS. service - LSB: Starts apcupsd daemon Loaded: loaded (/etc/init. Apr 11, 2019 · apcupsd is the background daemon, and also includes a command line utility, "apcupsd", that allows you to send some commands to the UPS. Second test, stop apcupsd from runing on startup, and reboot the machine. You can check with sudo systemctl status apcupsd. biz Normally, when properly installed, apcupsd will be started and stopped automatically by your system. type = Network & ShareUPS Disabled cable. Dec 1, 2000 · Because this article is about apcupsd, we will focus on American Power Conversion (APC) brand UPSes. If now the ups kils power, you probably have another program/process that tries on boot to use any serial port for something, and writes something Dec 17, 2021 · Unfortunately, the apctest command conflicts with the apcupsd daemon, so you need to stop apcupsd temporarily. It might be best for you to copy them from here and paste them into a text editor on your computer. You are currently viewing LQ as a guest. ' is now unchecked, despite apcupsd is running. service loaded failed failed APC UPS Monitor LOAD = Reflects whether the unit definition was properly loaded. 14 (31 May 2016) debian Checking configuration sharenet. I have a Pi connected to my Cyberpower UPS by USB, which is running acpupsd in NET MASTER mode, with all other devices running as NET SLAVE. 04, apcupsd wasn't actually running. Oct 4, 2023 · If I stop the apcupsd daemon, this does not happen, and the uninterruptible power supply works until the accumulator sits down. If utility power is not restored, a system shutdown will follow when the battery is exhausted, a specified timeout expires, a specified battery charge percentage is reached, or a 把搬寝之后闲置在家的UPS连到了Homelab上,顺便设置了一下关机指令保证自动关机的时候不会连带直接切断硬盘柜供电,让硬盘有足够的停转时间。 apcupsd in a container; can trigger arbitrary commands on the Docker host - gersilex/apcupsd-docker Apr 14, 2014 · APC is very well supported in Linux by open-source apcupsd. Goliath works as it should. ApcTest returns can't connect to socket (38). Apcupsd works with most of APC's Smart-UPS models as well as most simple signaling models such a Back-UPS, and BackUPS-Office. MSC. Unf Feb 23, 2021 · First stop the apcupsd daemon and then run apctest. The UPS model used in the examples is an APC SmartUPS 1000, but any APC or compatible model should work. Pretty much all other UPSes are supported by NUT, but for some strange reason APC has a separate project. events. apctest error termination completed The apcupsd is actually creating a lock file named "/var/lock/LCK. . d/apcupsd; bad; vendor preset: enabled) Active: active (exited) since Wed 2018-01-10 22:21:00 CET; 34min ago Docs: man:systemd Feb 16, 2023 · I've installed, purged and re-installed apcupsd 3 times always with this result. Feb 23, 2025 · In the very old days (~2012) with an APC Smart-UPS 1000 (SUA1000I) it was possible to set a few parameters with the 'apctest' cli tool (make sure to stop apcupsd before). Stop it first with sudo systemctl stop apcupsd, then try apctest. If now the ups kills power you are looking at firmware, apcupsd settings or faulty ups. 1 loaded units listed. The other two boxes are not always on. file exist Mon Jan 07, 2019 5:46 pm Feb 11, 2022 · apcupsd 3. Mar 26, 2021 · If I stop the apcupsd, then run the acptest command I get : chris@PMS1:~$ apctest 2021-03-26 22:26:01 apctest 3. Jul 25, 2011 · I am running 2 unraid servers Goliath and Spartacus and a Windows 2008r2 Server (Leviathan) on the same APC UPS. ACTIVE = The high-level unit activation state, i. STEP7. Having a problem installing a new program? Want to know which application is best for the job? Post your question in this forum. A few years ago i installed apcupsd and it worked out of the box but now, after a reinstall it just wont work. Click STOP. The settings look right in the apcupsd . Set battery date, set UPS name, and print EEPROM values should work. conf", and the right column reflects my changes to it. Goliath is on 24x7 so it is the master. " I assume I need to disable apcupsd (I'm using the NUT plugin for network UPS instead), and I've already set: Settings > UPS Settings > Start APC UPS daemon: No, but the message keeps appearing. Quick ideas: Stop apcupsd, let it settle for ~10 minutes, then service apcupsd start. The homepage describes apcupsd as: Apcupsd can be used for power management and controlling most of APC's UPS models on Unix and Windows machines. After adjusting the configuration file you can start and stop the apcups daemon via the Services menu page of the WUI. During a power failure or other event, apcupsd can execute a script of actions to take, such as broadcast a wall message to all users that there is a power problem, send an email alert or report, or Jul 8, 2021 · Hello, i installed apcupsd on my Centos 7 machine with an Back-UPS 700 and tested if it would shutdown the server properly in the case of a power failure before the battery runs flat. The first and most important task is to asynchronously notify when power events happen. Second, and perhaps less important Oct 11, 2018 · apcuspd - acptest won't run even though apcupsd is stopped and no LCK. Goliath has the master USB port to the APC UPS. Registration is quick, simple and absolutely free. type = USB UPS Driver Setting up the port apctest FATAL ERROR in apctest. type = USB Cable mode. Here's the rotated log Code: cat apcupsd. For the record, apt and aptitude give the same re My server that runs apcupsd is the largest load on my UPS, and whenever the power goes out I want to have the server shutdown and leave the UPS to run until the UPS shuts itself down on low battery voltage. The end goal is to make the UPS status available over the network so May 12, 2013 · Just went through the first log rotate; had a power outage which looked OK. Then you can launch apctest, which uses a menu-based interface. systemctl start apcupsd Oct 27, 2018 · The rub is that with the APCUPSD USB driver it will only work for the APCUPSD server which residents on ones USB connecting computer or use the standard Windows USB driver which accesses the PowerChute server which is resident on the UPS network card. 1 2013-05-07 15:25:49 -0400 Jun 16, 2006 · Why apcupsd? Because it works. -CMD (as admin) -cd to: C:\apcupsd\bin -type apcaccess. Is th The two columns below attempt to show the side by side differences between the APC Configuration File and what I changed it to for my own personal preferences. e. Mar 9, 2023 · Every 10 minutes the log is displaying "Tower apcupsd [2250]: Communications with UPS lost. − Implement very crude first cut of EEPROM programming in apctest. It broadcasts "ON BATTERY" an Stop apcupsd, then run sudo apctest, then do a self-test. If the power is Looking at the webui, 'Enable APC UPS Daemon service. To see the reason for the shutdown in logs, I commented out the commands for poweroff in the apccontrol file. To make it easier to notice the Feb 25, 2023 · @ bchan said in APCUPSD: How to power off UPS: The same UPS is powering a few other devices include a raspberry pi. c at line 319 Unable to open Mar 9, 2006 · Welcome to LinuxQuestions. Jun 28, 2021 · Stop Apcupsd service/daemon and edit apcupsd. conf Sep 6, 2023 · How to replace the battery pack on an APC Back-UPS BX700-GR. Jan 2, 2023 · This guide shows you how to set up apcupsd inside a LXC container for APC UPSes which utilize the PowerChute USB technology. A UPS protocol must accomplish two main tasks. Unfortunately, the details are different for each system. Find APCUPSD in the list. Here is what is output in journalct-u apcupsd Power failure on UPS invilso-systemproductname. Nov 15, 2018 · Part 1: Setting up InfluxDB, Grafana and Telegraf with Docker on Linux Part 2: Monitoring a UPS with Grafana on Linux Part 3: Grafana integration with 3rd party services such as Nest and weather. apctest error termination completed After stopping apcupsd, it does not show up when I type ps fax, so I don't believe \ that it is running, and yet this error occurs. When mains power is lost, followed by an APC UPS battery depletion, gracefully shutdown a Hubitat hub connected to the UPS, using Windows, VBS and apcupsd. Below, we give the commands for selected systems. During a power failure, apcupsd will inform the users about the power failure and that a Jun 16, 2006 · Why apcupsd? Because it works. After it finishes, you can also set the battery date (this is optional, and purely informative, it doesn't affect anything other than the BATTDATE output from apcaccess), exit apctest and start apcupsd again. Mar 15, 2021 · The problem Sensors unavailable What is version of Home Assistant Core has the issue? core-2021-3-4 What was the last working version of Home Assistant Core? core-2021-2-?? What type of installatio APCUPSD (8) System Manager's Manual APCUPSD (8) NAME apcupsd -- a daemon for controlling most APC UPSes SYNOPSIS apcupsd [-b] [-d level | --debug level] [-f file | --config-file file] [-P file | --pid-file file] [-p | --kill-on-powerfail | -t | --term-on-powerfail] [-R] apcupsd [-k | --killpower | --hibernate | -o | --power-off] apcupsd [-h | --help] apcupsd [-V | --version] DESCRIPTION The -first, stop apcupsd by: click START > PROGRAMS > APCUPSD > STOP-APCUPSD -you may have to stop the APCUPSD service: click START > RUN > SERVICES. The apcupsd driver should instruct the ups to power down without any action required on your part May 18, 2019 · APCUPSD with multiple UPS on Stretch Sat May 18, 2019 11:57 pm Dec 4, 2021 · On a Linux system simply running sudo service apcupsd stop or outright killing the process with the PID via a command like kill -TERM [PID] should be enough to stop the process. Below is the default settings in apcupsd. Aug 8, 2023 · I am running an APC SMT1500RMI2U connected to a Linux server via serial cable. If power is not restored, a system shutdown will follow when the battery is exhausted, a timeout (seconds) expires, or runtime expires based on internal APC calculations determined by power consumption rates. On the Linux server, the UPS is managed by apcupsd and the associated utilities. apcaccess is an additional utility that comes bundled with apcupsd, and is used to display current status information about the UPS. I am using apcupsd to manage my system in case of power outage. 14 (31 May 2016) slackware startup succeeded Communications with UPS lost Nov 18, 2012 · Linux - Software This forum is for Software issues. I've been working with APCUPSD to get my whole rack to shutdown gracefully near immediately on a power failure. During a power failure, apcupsd will inform the users about the power failure and that a shutdown may occur. More extensive details on usage and debugging of apctest can be found here at the University of Waterloo’s Wiki page on acupsd or in this blog post. UPSes from other manufacturers share the same general behavior but, to date, apcupsd does not communicate with non-APC UPSes. You cannot perform apctest when the service is started. exe to test/configure battery May 9, 2017 · If apcupsd or apctest is already running, please stop it and run this program again. Still trying to find the file with "ISCONFIGURED=yes" that is why I tried to stop apcupsd from running to use apctest. Feb 25, 2025 · Set up apcupsd to manage Eaton UPS on Debian Linux. 1 ## UPSNAME APC01 UPSTYPE usb DEVICE /dev/ugen0 LOCKFILE /var/spool/lock UPSCLASS standalone UPSMODE disable If apcupsd or apctest is already running, please stop it and run this program again. - arnbme/apcupsd Using apcupsd to Monitor a USB-Attached APC UPS This wiki page shows how to install and configure the apcupsd package to monitor and report the statistics for an APC branded USB attached Uninterruptible Power Supply (UPS). It didn't appear in ps aux | grep apc and I got: % systemctl status apcupsd apcupsd. The left column below is the original "apcupsd. I ran netstat and I don't see any other resources hogging the port, but I don't see Fixed − A bug report against the Mandrake version of apcupsd indicates that apcupsd is not releasing /dev/console. Starting/Stopping Apcupsd Start apcupsd: Jun 29, 2021 · I'm running UnRaid and trying to get it to connect to my 9617. May 25, 2020 · 1 If you can run apcaccess and get the output like shown, it means apcupsd is running. Oct 31, 2015 · ## apcupsd. I've moved the close() of STDIN so that it is always executed to prevent this possibility. The devices are set to shut down immediately, the Pi goes down after 10 minutes. In order to avoid degrading my UPS's battery for no reason, I . Learn how to configure power management, automatic shutdown, and logging. I did try the RS232 cable as well but would not even get the above info. Is th Apcupsd can be used for power management and controlling most of APC ’s UPS models, including Smart-UPS models as well as most simple signalling models such as Back-UPS and BackUPS-Office. com - coming soon Hi msinklair, thanks for the info, was trying to stop apcupsd to run apctest but I appear not to be able to stop apcusd which I guess is me typing in the wrong thing in the wrong place. exe to see stats -type apctest. The apcupsd driver should instruct the ups to power down without any action required on your part The two columns below attempt to show the side by side differences between the APC Configuration File and what I changed it to for my own personal preferences. com - coming soon apctest is a program that enables the running of certain low-level tests to check the operation of the attached simple signalling American Power Conversion Corp (APC) UPS and to check that your apcupsd (8) configuration is correctly setup and can establish communication with the UPS.